Interface block SB-T-HS-004-50A Item 37699

Downloads
Conformation of RoHS compliance (EN|PDF)
CAD file (INGUN_37699.STEP)
Document (37699__Kundenzeichnung.PDF)
Product datasheet (EN|pdf)
Choose version
SB-T-HS-004-50A (37699)
SB-P-HS-002-50A-1,0 (31550) SB-P-HS-004-50A-1,0 (37698) SB-P-HS-024-30A-1,0-Z (38700) INGUN SELECTION SB-T-HS-004-50A (37699) SB-T-HS-034-20A (31011) SB-T-HS-045-30A (30963) INGUN SELECTION SB-P-HS-008-50A-1,0 (35929) INGUN SELECTION SB-P-HS-045-30A-1,0 (16900) INGUN SELECTION SB-T-HS-002-50A (31549) SB-T-HS-008-50A (35549) INGUN SELECTION SB-T-HS-024-30A-Z (38699) INGUN SELECTION SB-T-HS-045-30A-Z (38697) SB-P-HS-008-50A-1,0-L (111830) SB-T-HS-008-50A-L (111831) SB-P-HS-024-30A-1,0 (27620) INGUN SELECTION SB-P-HS-034-20A-1,0 (31009) SB-P-HS-045-30A-1,0-Z (38698) SB-T-HS-024-30A (27628) INGUN SELECTION
Here you can optionally configure a new variant:
Technical data
General data
Product group : Interface blocks (SB)
Series : SB-HS
Type : High-current block
Version : Test system side
Accessory type : Customising accessory
Component assembly : HSS-150-0025 & KS-150M3M3-R
Weight : 0.031 kg
Min. temperature : - 30 °C
Max. temperature : + 120 °C
RoHS-compliant : RoHS-3;6c
Electrical data
Typical resistance (Ri) of one GKS : < 10 mOhm
Technical data
Working distance : 15.1 +/- 0.5 mm
Centring pin : - mm
Connection : M3 thread-post
Number of poles : 4 (fixe Pos.)
GKS working stroke : 4.4 mm
Air distance (not wired) : 9.1 mm
Spring force : 20 N
Max. current of one GKS : 50 A
Max. current of all GKS : 35 A
Max. voltage : 6000 V
Max. power loss : 25 W
Min. line cross-section : 6 mm²
Compatible with
Compatible mating part 1 : SB-P-HS-004-50A-1,0
Manual test fixtures (MA) : MA 21xx, MA 32xx
Pylon receiver : Pylon

Mating component

Interface block SB-P-HS-004-50A-1,0 Item 37698
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals

Manual test fixture

INGUN SELECTION MA 2113/D/H/S-10/HG
Manual test fixture MA 2113/D/H/S-10/HG Item 32700
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/VPC-S6 Item 33040
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/VPC-G12 Item 46040
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/HG/GR2270/71 Item 33457
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/KMFT Item 32735
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/HG/S-10/MCP-Sco/OS Item 47540
  • Manual interchangeable test fixture with parallel closing drive mechanism for testing medium quantities of PCBs in the highest quality and high-precision design.
  • Prepared for mounting the test system interface MC-Panel ITA Scout-21
  • Test system interface MC-Panel ITA Scout-21 not included in delivery
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/HG/VPC-G12 Item 46730
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 3213/D/H/S-10/HG Item 49580
  • Manual test fixtures with parallel closing drive mechanism for testing large PCB quantities with the highest quality and precision
  • Ultra-robust long-life test fixture with increased parallel stroke of 21 mm
  • Interchangeable test fixture without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/VPC-G20x Item 49480
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2111/D/H/S-5
Manual test fixture MA 2111/D/H/S-5 Item 31730
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 3212/D/H/S-7 Item 43630
  • Manual test fixtures with parallel closing drive mechanism for testing large PCB quantities with the highest quality and precision
  • Ultra-robust long-life test fixture with increased parallel stroke of 21 mm
  • Interchangeable test fixture without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/GR2270/71 Item 33448
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/PYLON-12 Item 33679
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2114/D/H/S-10 Item 34350
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2111/D/H/S-5/HG Item 33420
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/SEICA-CD Item 108699
  • Manual test fixture with parallel closing drive mechanism for testing medium quantities of printed circuit boards in the highest quality and small number of versions.
  • Interchangeable kit test fixtures with preconfigured SEICA Compact-Digital test system interface
  • Desk housing with handles
  • Modular, configurable internal interface for up to 10 interface blocks
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/PYLON-12 Item 33681
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2112/D/H/S-7
Manual test fixture MA 2112/D/H/S-7 Item 32660
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/MTS300 Item 33443
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2113/D/H/S-10
Manual test fixture MA 2113/D/H/S-10 Item 32500
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/HG/PYLON-12 Item 33678
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/KS-i1000 Item 42600
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/VPC-G12x Item 37799
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/SPEA 3030 Item 32701
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/MCP-Titan/OS Item 40978
  • Manual interchangeable test fixture with parallel closing drive mechanism for testing medium quantities of PCBs in the highest quality and high-precision design.
  • Prepared for mounting the test system interface MC-Panel ITA Titan Hz
  • MC-Panel ITA Titan Hz not included in delivery
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 3212/D/H/S-7/HG Item 55760
  • Manual test fixtures with parallel closing drive mechanism for testing large PCB quantities with the highest quality and precision
  • Ultra-robust long-life test fixture with increased parallel stroke of 21 mm
  • Interchangeable test fixture without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/S-7/SPEA3030 Item 37970
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2112/D/H/S-7/HG
Manual test fixture MA 2112/D/H/S-7/HG Item 33460
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/KMFT Item 38871
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 3213/D/H/S-10 Item 43580
  • Manual test fixtures with parallel closing drive mechanism for testing large PCB quantities with the highest quality and precision
  • Ultra-robust long-life test fixture with increased parallel stroke of 21 mm
  • Interchangeable test fixture without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/PYLON-12 Item 33688
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2114/D/H/S-10/HG Item 42290
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 3211/D/H/S-5 Item 43950
  • Manual test fixtures with parallel closing drive mechanism for testing large PCB quantities with the highest quality and precision
  • Ultra-robust long-life test fixture with increased parallel stroke of 21 mm
  • Interchangeable test fixture without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2109/D/H/S-5
Manual test fixture MA 2109/D/H/S-5 Item 34340
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Exchangeable kits in standard and ESD versions, which can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/VPC-G12 Item 35904
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/GR2270/71 Item 32920
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 3214/D/H/S-10 Item 43960
  • Manual test fixtures with parallel closing drive mechanism for testing large PCB quantities with the highest quality and precision
  • Ultra-robust long-life test fixture with increased parallel stroke of 21 mm
  • Interchangeable test fixture without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/VPC-G12 Item 35503
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/GR2270/71 Item 33462
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring

Receiver

Receiver RC-PYLON-12-V2 Item 32162
  • Pylon receiver for test fixture with Pylon interface
  • One-handed operation
  • Tightening mechanism with guided latch via clearance-free gear-wheel drive
  • Includes earth contact, visibility strip, and protective earth wiring
  • High flexibility and modularity in terms of signal transmission using interface blocks