Manual test fixture MA 2112/D/H/S-7/PYLON-12 Item 33681

Downloads
Conformation of RoHS compliance (EN|PDF)
Product datasheet (EN|pdf)
CAD file (INGUN_33681.STEP)
Document (33681__Kundenzeichnung.PDF)
CAD file (INGUN_33681_open.STEP)
Choose version
MA 2112/D/H/S-7/PYLON-12 (33681)
MA 2112/D/H/S-7/HG (33460) INGUN SELECTION MA 2112/D/H/S-7/KMFT (32735) MA 2112/S-7/SPEA3030 (37970) MA 2112/D/H/S-7 (32660) INGUN SELECTION MA 2112/D/H/S-7/GR2270/71 (33462) MA 2112/D/H/S-7/PYLON-12 (33681) MA 2112/D/H/S-7/VPC-G12 (35503) MA 2112/D/H/S-7/HG/GR2270/71 (33457) MA 2112/D/H/S-7/HG/PYLON-12 (33678) MA 2112/D/H/S-7/HG/VPC-G12 (46730) MA 2112/D/H/S-7/MCP-Titan/OS (40978) MA 2112/D/H/S-7/VPC-S6 (33040)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Manual test fixtures (MA)
Main series : MA xxxx
Series : MA 21xx
Series : MA 2112
Size : xx12
Test fixture type : Exchangeable test fixture
Contact stroke generation : Manual
Housing type : Desk housing
Max. interface signals : 1190
Interface blocks required : Test system side
Max. internal interface blocks : 7
Contacting direction : Single-sided (bottom)
Max. contact force : 2000 N
Approx. parallel contact stroke : 15 mm
Test system interface : Rohde & schwarz pylon
Weight : 12.1 kg
Min. temperature : + 10 °C
Max. temperature : + 60 °C
Low voltage : Yes, with suitable additional option
ESD-compliant : Yes, with suitable exchangeable kit
RoHS-compliant : RoHS-3;6c
Technical data
Test probe installation height, top : 16 mm
Test probe installation height, bottom : 10.5 mm
Test probe installation height, dual-stage, bottom : 16 mm
Free space above PCB : 58 mm
Force of gas pressure springs : 300 N (L: 100 N / R: 200 N)
Pressure frame closing force : 120 N
Pressure frame opening angle : 75 °
Standard version : Yes, with suitable exchangeable kit
Useable area, standard (WxD) : 285 x 240 mm
ESD version : Yes, with suitable exchangeable kit
Useable area, ESD (WxD) : 285 x 240 mm
Radio frequency version : Yes, with suitable exchangeable kit
Useable area, radio frequency (WxD) : 215 x 180 mm
Rigid pin version : Yes, with suitable exchangeable kit
Useable area, rigid pin (WxD) : 255 x 220 mm
Dual-stage version : Yes, with suitable additional option
Useable area, dual-stage (WxD) : 285 x 240 mm
Additional contacting unit (ZSK), top : Yes, with suitable additional option
Outer dimensions, open (WxDxH) : 501 x 495 x 583 mm
Outer dimensions, closed (WxDxH) : 501 x 548 x 262 mm

Functional units

Functional unit FB-MAxxxx
  • Upgrade kits to make operation easier, increase the testing reliability, and to reduce handling times
  • Available for manual test fixtures and exchangeable kits
  • Wide range of varying functions
Fixture interface AS
  • Trusted fixture interfaces with precise guidance for the highest precision
  • Fully loaded or loaded versions for individual configurations
  • Available as component for popular test systems

Spare parts

Spare part kit ETK-MAxxxx
  • Available for each component as kit or individual part including assembly drawing for easy replacement and safe installation
  • Quick, easy maintenance
  • Easy replacement by operators on site

Interface blocks

Interface block SB-VA
  • Compatible with Pylon interface or Pylon receiver
  • To connect vacuum hose PG16
Interface block SB-HF
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-SO
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-BLP
  • Can be used in all test fixtures with internal or external pylon interface
  • To cover unused spaces for interface blocks
Interface block SB-MB
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of several signal combinations
Interface block SB-PN
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of compressed air
Interface block SB-SI
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-LL
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of light signals
Interface block SB-HS
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-HSD
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of high-speed digital (HSD) signals

MA exchangeable kits

Exchangeable kit ATS MA12
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)