Manual test fixture MA 3213/D/H/S-10/HG Item 49580

Downloads
Conformation of RoHS compliance (EN|PDF)
CAD file (INGUN_49580_open.STEP)
CAD file (INGUN_49580.STEP)
Product datasheet (EN|pdf)
CAD file (INGUN_49580.STEP)
Choose version
MA 3213/D/H/S-10/HG (49580)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Manual test fixtures (MA)
Main series : MA xxxx
Series : MA 32xx
Series : MA 3213
Size : xx13
Test fixture type : Exchangeable test fixture
Contact stroke generation : Manual
Housing type : High desk housing
Max. interface signals : 1700
Interface blocks required : Test system side
Max. internal interface blocks : 10
Contacting direction : Double-sided (top/bottom side)
Max. contact force : 2000 N
Approx. parallel contact stroke : 22 mm
Test system interface : Not pre-wired
Weight : 18.94 kg
Min. temperature : + 10 °C
Max. temperature : + 60 °C
Low voltage : Yes, with suitable additional option
ESD-compliant : Yes, with suitable exchangeable kit
RoHS-compliant : RoHS-3;6c
Technical data
Test probe installation height, top : 16 mm
Test probe installation height, bottom : 10.5 mm
Test probe installation height, dual-stage, bottom : 16 mm
Free space above PCB : 58 mm
Force of gas pressure springs : 400 N (L: 200 N / R: 200 N)
Pressure frame closing force : 70 N
Pressure frame opening angle : 75 °
Standard version : Yes, with suitable exchangeable kit
Useable area, standard (WxD) : 440 x 310 mm
ESD version : Yes, with suitable exchangeable kit
Useable area, ESD (WxD) : 440 x 310 mm
Radio frequency version : Yes, with suitable exchangeable kit
Useable area, radio frequency (WxD) : 375 x 240 mm
Rigid pin version : No
Dual-stage version : Yes, with suitable additional option
Useable area, dual-stage (WxD) : 440 x 310 mm
Additional contacting unit (ZSK), top : Yes, with suitable additional option
Outer dimensions, open (WxDxH) : 648 x 533 x 770 mm
Outer dimensions, closed (WxDxH) : 648 x 601 x 370 mm