Manual test fixture MA 2113T/D/H/2xS-5/PYLON-12 Item 33680

Downloads
Conformation of RoHS compliance (EN|PDF)
Document (33680__Kundenzeichnung.PDF)
Product datasheet (EN|pdf)
CAD file (INGUN_33680_open.STEP)
CAD file (INGUN_33680.STEP)
Choose version
MA 2113T/D/H/2xS-5/PYLON-12 (33680)
MA 2113T/D/H/2xS-5/PYLON-12 (33680) MA 2113T/D/H/2xS-5/MTS300 (33380) MA 2113T/D/H/2xS-5/VPC-G12x (57940) MA 2113T/D/H/2xS-5/HG (36666) MA 2113T/D/H/2xS-5/HG/VPC-G12 (46770) MA 2113T/D/H/2xS-5 (32300) MA 2113T/D/H/2xS-5/VPC-G12 (46405)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Manual test fixtures (MA)
Main series : MA xxxx
Series : MA 21xx
Series : MA 2113T
Size : xx13T
Test fixture type : Tandem exchangeable test fixture
Contact stroke generation : Manual
Housing type : Desk housing
Max. interface signals : 1700
Interface blocks required : Test system side
Max. internal interface blocks : 2 x 5
Contacting direction : Single-sided (bottom)
Max. contact force : 2000 N
Approx. parallel contact stroke : 15 mm
Test system interface : Rohde & schwarz pylon
Weight : 16.25 kg
Min. temperature : + 10 °C
Max. temperature : + 60 °C
Low voltage : Yes, with suitable additional option
ESD-compliant : Yes, with suitable exchangeable kit
RoHS-compliant : RoHS-3;6c
Technical data
Test probe installation height, top : 16 mm
Test probe installation height, bottom : 10.5 mm
Test probe installation height, dual-stage, bottom : 16 mm
Free space above PCB : 58 mm
Pressure frame closing force : 120 N
Force of gas pressure springs : 200 N (L: 100 N / R: 100 N)
Pressure frame opening angle : 75 °
Standard version : Yes, with suitable exchangeable kit
Useable area, standard (WxD) : je 150 x 240 mm
ESD version : Yes, with suitable exchangeable kit
Useable area, ESD (WxD) : je 150 x 240 mm
Radio frequency version : Yes, with suitable exchangeable kit
Useable area, radio frequency (WxD) : je 100 x 160 mm
Rigid pin version : No
Dual-stage version : Yes, with suitable additional option
Useable area, dual-stage (WxD) : je 150 x 240 mm
Additional contacting unit (ZSK), top : Yes, with suitable additional option
Outer dimensions, open (WxDxH) : 654 x 564 x 583 mm
Outer dimensions, closed (WxDxH) : 654 x 564 x 262 mm

Functional units

ESD customisation with PE wiring FB-ESD-S-MAxx13T Item 113081
  • ESD customisation with PE wiring and shock-proof protection
  • Assembly kit for independent, on-site assembly
  • Includes detailed installation instructions for professional installation
  • Incl. proposal for the test protocols for testing the ESD discharge and the PE wiring with shock-proof protection
Protective earth wiring FB-SLV-MAxx13T Item 112475
  • PE wiring and shock-proof protection
  • Assembly kit for independent, on-site assembly
  • Can be used for single-stage and dual-stage contacting
  • Includes detailed installation instructions for professional installation
  • Includes proposed measurement protocol to record the measured values
  • Cable cross-section: inner cables 1.5 mm², outer cables 4.0 mm²
ESD customisation FB-ESD-MAxx13T Item 113915
  • Complete kit for self-assembly, for individually configurabl ESD customisation
  • Compatible with MA xx13T test fixtures
  • Quick, easy installation with only minor reworking
  • Incl. detailed assembly instructions for professional customisation
  • Incl. template for measurement protocol for standard-compliant measurement

MA exchangeable kits

Exchangeable kit ATS MA11/S-5/HF/AL/ESD Item 154111
  • Radio-frequency exchangeable kit with integrated RF interface and service cover
  • High-precision RF chamber made from aluminium
  • Outstanding shielding in the frequency range up to 6 GHz
  • Quick, tool-free set-up, can be used without readjustment
  • Optional RF absorber to set up an internal radio network
  • Optional EMC-compliant RF transmissions for connecting the measurement signals
Exchangeable kit ATS MA11/S-5/ESD Item 46026-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/ESD Item 46248-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/S-5 Item 45898-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/HF/AL/ESD Item 154011
  • Radio-frequency exchangeable kit with integrated RF interface and service cover
  • High-precision RF chamber made from aluminium
  • Outstanding shielding in the frequency range up to 6 GHz
  • Quick, tool-free set-up, can be used without readjustment
  • Optional RF absorber to set up an internal radio network
  • Optional EMC-compliant RF transmissions for connecting the measurement signals
Exchangeable kit ATS MA11 Item 45900-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)

Interface blocks

Interface block SB-P-PN-008-PK3-A Item 37821
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of compressed air
Interface block SB-P-HF-016-4GHz-08-Z Item 38178
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-008-6GHz-06-Z Item 42629
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-4GHz-Z Item 34571
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-06 Item 38165
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HS-045-30A-1,0 Item 16900
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-P-HF-016-4GHz-10-Z Item 38176
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-10 Item 38161
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-08 Item 38163
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-MB-20/20-30A/DM2,3 Item 45305
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of several signal combinations
Interface block SB-P-HF-016-4GHz-06-Z Item 38180
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-4GHz-07-Z Item 38179
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HS-045-30A-1,0-Z Item 38698
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-P-PN-008-PK3 Item 27622
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of compressed air
Interface block SB-P-HF-016-0,7GHz-12 Item 38159
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SI-170-4A-0,6-RD Item 52313
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-HF-016-4GHz-03-Z Item 38183
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-008-6GHz-03-Z Item 42708
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-008-6GHz-04-Z Item 42707
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-14 Item 38157
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-008-6GHz-Z Item 42627
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-01 Item 38170
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SO-010-IDC Buchse Item 37662
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-P-HF-016-4GHz-12-Z Item 38174
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HS-024-30A-1,0 Item 27620
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-P-HF-016-0,7GHz-09 Item 38162
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SI-085-4A-0,6 Item 44271
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-SO-020-IDC Buchse Item 56694
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-P-SO-016-IDC Buchse Item 56990
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-P-SO-002-USB-RJ45 Item 54752
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-P-HS-034-20A-1,0 Item 31009
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-P-HF-008-6GHz-01-Z Item 42717
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-008-6GHz-07-Z Item 42628
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SO-009-SUB-D Item 35909
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-P-HF-004-18GHz-02 Item 55752
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HS-002-50A-1,0 Item 31550
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-P-SI-040-4A-0,6 Item 37074
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-MB-20/4-30A/PK3-A Item 50581
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of several signal combinations
Interface block SB-P-SI-040-4A-0,6-Z Item 42339
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-SO-002-Polklemme Item 35910
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-P-HF-016-4GHz-15-Z Item 38171
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-07 Item 38164
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-13 Item 38158
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-05 Item 38166
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SO-002-USB-3-Buchse Item 45557
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-P-SI-136-4A-0,6-Z Item 109467
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-HF-016-4GHz-01-Z Item 38185
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-4GHz-14-Z Item 38172
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-MB-20/4-30A/PK3 Item 31867
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of several signal combinations
Interface block SB-P-HF-016-0,7GHz Item 31002
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-LL-045-DM1,0 Item 41020
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of light signals
Interface block SB-P-HF-016-4GHz-13-Z Item 38173
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-LL-045-DM2,3 Item 29448
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of light signals
Interface block SB-P-SO-026-IDC Buchse Item 56698
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-P-HS-004-50A-1,0 Item 37698
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-P-HF-008-6GHz-02-Z Item 42716
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-4GHz-02-Z Item 38184
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SI-136-4A-0,6 Item 33665
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-HF-016-0,7GHz-11 Item 38160
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-02 Item 38169
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-03 Item 38168
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-VA-001-PG16 Item 109725
  • Compatible with Pylon interface or Pylon receiver
  • To connect vacuum hose PG16
Interface block SB-P-HS-024-30A-1,0-Z Item 38700
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-P-HF-016-0,7GHz-04 Item 38167
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SI-062-4A-25 Item 109434
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-HF-008-6GHz-05-Z Item 42706
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-004-18GHz Item 35532
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-0,7GHz-15 Item 38156
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SI-170-4A-0,6-Z Item 38692
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-LL-024-DK1,5-Z Item 30211
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of light signals
Interface block SB-P-SI-085-4A-0,6-Z Item 42344
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-P-HF-016-4GHz-11-Z Item 38175
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-004-18GHz-03 Item 55753
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-4GHz-09-Z Item 38177
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-004-18GHz-01 Item 55751
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HF-016-4GHz-05-Z Item 38181
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-HS-008-50A-1,0 Item 35929
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-P-HF-016-4GHz-04-Z Item 38182
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-P-SI-170-4A-0,6 Item 13515
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories