Dual-stage locking unit SO FB-2VM-SO-MA2xxx Item 110515

Downloads
Conformation of RoHS compliance (EN|PDF)
CAD file (INGUN_110515.STEP)
Product datasheet (EN|pdf)
Document (110515_Montagezeichnung.PDF)
CAD file (INGUN_110515.STEP)
Document (110515__Kundenzeichnung.PDF)
Choose version
FB-2VM-SO-MA2xxx (110515)
FB-ADT-MAxxxx (40980) FB-ESD-MAxx09/11/12/13/14 (33482) FB-KSG-ER-MAxx13/13T (111802) FB-MPZ-MAxx11 (104135) FB-MPZ-MAxx14 (104740) FB-SIS-BM-MAxx12 (41558) FB-SIS-BM-MAxx13 (41556) FB-SIS-BM-MAxx14 (41553) FB-SIS-ZSO-MA2xxx (36210) INGUN SELECTION FB-SOE-MAxx11/12/13/13T/14 (45220) FB-VER-O-ESO-MAxxxx (43584) FB-VLK-MA2xxx (43763) FB-2VM-MA2xxx (106834) FB-2VM-MOT-MAxxxx (112801) FB-STE-2VM-MAxxxx (111185) FB-SLV-MAxx13 (112473) FB-SLV-MAxx14 (112474) FB-SLV-MAxx09 (113130) FB-KSG-ER-MAxx12 (111799) FB-SIS-OSA-MAxx14 (114826) FB-LED-D-MAxx09/11/13T (115452) FB-GDS-600N-MAxxxx (115295) FB-ABF-G-I-MA2xxx (37550) FB-ABF-V-SKS-MAxxxx (43246) FB-LED-MAxx09/11/13T (45770) FB-LED-MAxx12 (45996) FB-LED-MAxx13 (45999) FB-MGK-MAxxxx (47715) FB-MPZ-MAxx09 (104734) FB-MPZ-MAxx13 (104738) FB-OBR-MA2xxx (43592) FB-OLB-MAxxxx (51770) FB-SIS-BM-MA2x09/11/13T (41560) FB-SIS-MA2xxx (42066) FB-SIS-ZSG-MA2xxx (46020) FB-STE-UNI-MAxxxx (42703) FB-VER-G-ESG-MAxxxx (32665) FB-SLV-MAxx11 (112471) FB-SLV-MAxx13T (112475) FB-2VM-MA3xxx (106841) FB-2VM-SO-MA3xxx (110538) FB-MPZ-MAxx12 (104578) FB-OSA-E-MA2x11/12 (113401) FB-SIS-OSA-MAxx12 (113450) FB-ESD-MAxx13T (113915) FB-LED-D-MAxx14 (115560) FB-FK-OSA-E (115618) FB-ABF-G-S-MA2xxx (33840) FB-ABF-V-I-MA2xxx (43625) FB-ABF-V-I-MA32xx (46745) FB-GDS-400N-MAxxxx (48730) FB-KSG-ER-MAxx14 (110707) FB-KSG-MAxxxx (29805) FB-SOP-MA2x09 (42701) FB-SOP-MAxx11/12/13/13T/14 (42700) FB-STE-MAG-MAxxxx (42810) FB-VER-G-ESO-MAxxxx (36065) INGUN SELECTION FB-VER-G-P-MAxxxx (49270) FB-VLK-MA32xx (44831) FB-SLV-MAxx12 (112472) FB-OSA-E-MA3211/12 (114445) FB-2VM-SO-MA2xxx (110515) FB-ESD-S-MAxx09/11/12/13/14 (43597) FB-ESD-S-MAxx13T (113081) FB-STE-LED-MAxxxx (113999) FB-GDS-300N-MAxxxx (62852) FB-OSA-E-MA2x13/14 (114263) FB-OSA-E-MA2x09 (114503) FB-SIS-OSA-MAxx13 (114287) FB-SIS-OSA-MAxx11 (114316) FB-SIS-OSA-MAxx09 (114509) FB-LED-D-MAxx12 (115218) FB-LED-D-MAxx13 (115559)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Functional units
Series : FB-MAxxxx
Type : Dual-stage limit
Version : Mechanical with electric motor
Accessory type : Additional function
Scope of delivery : Pre-assembled
Material : 3.3547, hard-coated
Width : 15 mm
Height : 101 mm
Weight : 0.56 kg
Min. temperature : + 10 °C
Max. temperature : + 60 °C
RoHS-compliant : -
Technical data
Connection : Cable
Installation : Thread M5
Max. voltage : 36 VDC
Number of poles : 3
Length : 118 mm
Cable length : 350 mm
Outer dimensionS (WxDxH) : 15 x 118 x 101 mm
Compatible with
Manual test fixtures (MA) : MA 2xxx
For dual-stage contacting : Yes

Manual test fixture

Manual test fixture MA 2112/D/H/S-7/VPC-G12 Item 35503
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/HG/VPC-G12 Item 46730
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/GR2270/71 Item 33462
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2113/D/H/S-10/HG
Manual test fixture MA 2113/D/H/S-10/HG Item 32700
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/KMFT Item 38871
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/SEICA-CD Item 108699
  • Manual test fixture with parallel closing drive mechanism for testing medium quantities of printed circuit boards in the highest quality and small number of versions.
  • Interchangeable kit test fixtures with preconfigured SEICA Compact-Digital test system interface
  • Desk housing with handles
  • Modular, configurable internal interface for up to 10 interface blocks
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/KS-i1000 Item 42600
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/HG/S-10/MCP-Sco/OS Item 47540
  • Manual interchangeable test fixture with parallel closing drive mechanism for testing medium quantities of PCBs in the highest quality and high-precision design.
  • Prepared for mounting the test system interface MC-Panel ITA Scout-21
  • Test system interface MC-Panel ITA Scout-21 not included in delivery
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/MCP-Titan/OS Item 40978
  • Manual interchangeable test fixture with parallel closing drive mechanism for testing medium quantities of PCBs in the highest quality and high-precision design.
  • Prepared for mounting the test system interface MC-Panel ITA Titan Hz
  • MC-Panel ITA Titan Hz not included in delivery
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/PYLON-12 Item 33681
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/KMFT Item 32735
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/SPEA 3030 Item 32701
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/PYLON-12 Item 33679
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/GR2270/71 Item 32920
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/VPC-S6 Item 33040
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/VPC-G20x Item 49480
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2112/D/H/S-7
Manual test fixture MA 2112/D/H/S-7 Item 32660
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/MTS300 Item 33443
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2113/D/H/S-10
Manual test fixture MA 2113/D/H/S-10 Item 32500
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/HG/PYLON-12 Item 33678
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/VPC-G12x Item 37799
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/GR2270/71 Item 33448
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/VPC-G12 Item 35904
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2111/D/H/S-5
Manual test fixture MA 2111/D/H/S-5 Item 31730
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/VPC-G12 Item 46040
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/HG/GR2270/71 Item 33457
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/PYLON-12 Item 33688
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2112/D/H/S-7/HG
Manual test fixture MA 2112/D/H/S-7/HG Item 33460
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/S-7/SPEA3030 Item 37970
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2111/D/H/S-5/HG Item 33420
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring