Rigid pin cover SNH-086-134-ATSMA09 Item 109244-KIT

Downloads
Conformation of RoHS compliance (EN|PDF)
Product datasheet (EN|pdf)
CAD file (INGUN_109244-KIT.STEP)
Document (109244-KIT_Montage__Kundenzeichnung.PDF)
Choose version
SNH-086-134-ATSMA09 (109244-KIT)
SNH-086-134-ATSMA09 (109244-KIT) SNH-086-204-ATSMA11 (109248-KIT) SNH-226-204-ATSMA12 (108795-KIT) SNH-381-274-ATSMA13 (109252-KIT) SNH-481-274-ATSMA14 (109256-KIT)
Here you can optionally configure a new variant:
Technical data
General data
Product group : ATS MA upgrade kits
Subseries : ATS MAxx
Series : SNH
Version : ESD without interface
Scope of delivery : Unassembled
Min. temperature : + 10 °C
Max. temperature : + 60 °C
RoHS-compliant : RoHS-3;6c
Technical data
Pushrod length : 60 mm
Free space above PCB : 58 mm
Useable area (WxD) : 86 x 134 mm
Outer dimensionS (WxDxH) : 113 x 161 x 52 mm
Compatible with
Exchangeable kit(s) (ATS) : ATS MA09

Pushrod

Push rod NHS-ST-60,0-6,0-KU-AL-ESD Item 43611
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
INGUN SELECTION NHS-ST-60,0-6,0-PA-AL
Push rod NHS-ST-60,0-6,0-PA-AL Item 18870
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
INGUN SELECTION NHS-ST-60,0-2,5-POM-AL
Push rod NHS-ST-60,0-2,5-POM-AL Item 21615
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
Push rod NHS-ST-60,0-4,0-KU-AL-ESD Item 23190
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
INGUN SELECTION NHS-ST-60,0-2,5-KU-AL-ESD
Push rod NHS-ST-60,0-2,5-KU-AL-ESD Item 43612
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation

MA exchangeable kits

Exchangeable kit ATS MA09/S-5/ESD Item 46233-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09 Item 45994-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09/ESD Item 46245-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09/S-5 Item 45990-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)