Manual test fixture MA 2013T/D/H Item 100985

Downloads
Conformation of RoHS compliance (EN|PDF)
Product datasheet (EN|pdf)
CAD file (INGUN_100985_open.STEP)
CAD file (INGUN_100985.STEP)
Document (100985__Kundenzeichnung.PDF)
Choose version
MA 2013T/D/H (100985)
MA 2013T/D/H (100985)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Manual test fixtures (MA)
Main series : MA xxxx
Subseries : MA 20xx
Series : MA 2013T
Size : xx13T
Test fixture type : Stand-alone test fixture
Contact stroke generation : Manual
Housing type : Desk housing
Max. interface signals : 1700
Interface blocks required : No
Contacting direction : Single-sided (bottom)
Max. contact force : 2000 N
Approx. parallel contact stroke : 15 mm
Test system interface : Not pre-wired
Weight : 22 kg
Min. temperature : + 10 °C
Max. temperature : + 60 °C
Low voltage : Yes, with suitable additional option
ESD-compliant : No
RoHS-compliant : RoHS-3;6a;6b;6c
Technical data
Test probe installation height, top : 16 mm
Test probe installation height, bottom : 10.5 mm
Test probe installation height, dual-stage, bottom : 16 mm
Free space above PCB : 58 mm
Force of gas pressure springs : 200 N (L: 100 N / R: 100 N)
Pressure frame opening angle : 69 °
Standard version : Yes
Useable area, standard (WxD) : 2x 150 x 240 mm
ESD version : No
Radio frequency version : No
Rigid pin version : No
Dual-stage version : Yes, with suitable additional option
Useable area, dual-stage (WxD) : 2x 150 x 240 mm
Additional contacting unit (ZSK), top : Yes, with suitable additional option
Outer dimensions, open (WxDxH) : 647 x 533 x 591 mm
Outer dimensions, closed (WxDxH) : 647 x 533 x 270 mm

MA exchangeable kits

INGUN SELECTION ATS MA11/S-5/ESD
Exchangeable kit ATS MA11/S-5/ESD Item 46026-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/ESD Item 46248-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA11/S-5
Exchangeable kit ATS MA11/S-5 Item 45898-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/S-5/HF/AL/ESD Item 154111
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
INGUN SELECTION ATS MA11
Exchangeable kit ATS MA11 Item 45900-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/HF/AL/ESD Item 154011
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment