Technical data
General data
Product group : ATS MA upgrade kits
Subseries : ATS MAxx
Series : SNH
Version : ESD without interface
Scope of delivery : Unassembled
Min. temperature : + 10 °C
Max. temperature : + 60 °C
RoHS-compliant : RoHS-3;6c
Technical data
Pushrod length : 60 mm
Free space above PCB : 58 mm
Useable area (WxD) : 481 x 274 mm
Outer dimensionS (WxDxH) : 509 x 301 x 52 mm
Compatible with
Exchangeable kit(s) (ATS) : ATS MA14
INGUN SELECTION NHS-ST-60,0-2,5-POM-AL
Push rod NHS-ST-60,0-2,5-POM-AL Item 21615
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
INGUN SELECTION NHS-ST-60,0-6,0-PA-AL
Push rod NHS-ST-60,0-6,0-PA-AL Item 18870
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
Push rod NHS-ST-60,0-4,0-KU-AL-ESD Item 23190
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
Push rod NHS-ST-60,0-6,0-KU-AL-ESD Item 43611
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
INGUN SELECTION NHS-ST-60,0-2,5-KU-AL-ESD
Push rod NHS-ST-60,0-2,5-KU-AL-ESD Item 43612
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
Exchangeable kit ATS MA14/S-10 Item 45983-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14 Item 45985-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/ESD Item 46257-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/S-10/ESD Item 46242-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/HF/AL/ESD Item 154014
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA14/S-10/CRS Item 108814
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2114, MA 3214
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
Exchangeable kit ATS MA14/S-10/HF/AL/ESD Item 154114
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment