Push rod NHS-ST-60,0-2,5-KU-AL-ESD Item 43612

Downloads
Conformation of RoHS compliance (EN|PDF)
CAD file (INGUN_43612.STEP)
Document (43612__Kundenzeichnung.PDF)
Product datasheet (EN|pdf)
Choose version
NHS-ST-60,0-2,5-KU-AL-ESD (43612) INGUN SELECTION
NHS-ST-20,0-6,0-PA-D3 (18742) NHS-ST-41,0-2,5-POM-AL (17714) NHS-ST-50,0-2,5-POM-AL (26927) NHS-ST-55,0-2,5-POM-AL (17326) NHS-ST-55,6-4,0-KU-AL-ESD (23342) NHS-ST-70,0-2,5-POM-AL (35922) NHS-ST-60,0-2,5-POM-AL (21615) INGUN SELECTION NHS-ST-60,0-6,0-KU-AL-ESD (43611) NHS-ST-15,0-5,0-KU-D3-ESD (25856) NHS-ST-20,0-2,5-KU-D3-ESD (23057) NHS-ST-20,0-6,0-KU-D3-ESD (23503) NHS-ST-51,0-2,5-POM-AL (19813) NHS-ST-51,0-6,0-PA-AL (19815) NHS-ST-55,6-2,5-KU-AL-ESD (23504) NHS-ST-55,6-6,0-KU-AL-ESD (23505) NHS-ST-60,0-6,0-PA-AL (18870) INGUN SELECTION NHS-ST-63,0-6,0-PA-AL (21577) NHS-ST-60,0-2,5-KU-AL-ESD (43612) INGUN SELECTION NHS-ST-15,0-5,0-POM-D3 (12681) NHS-ST-20,0-2,5-POM-D3 (17340) NHS-ST-20,0-2,5-POM-M3 (22661) INGUN SELECTION NHS-ST-20,0-4,0-KU-D3-ESD (19315) NHS-ST-28,0-2,5-POM-AL (23571) NHS-ST-34,0-2,5-POM-AL (28785) NHS-ST-36,4-2,5-POM-AL (17712) NHS-ST-55,3-2,5-POM-AL (17325) NHS-ST-55,6-2,5-POM-AL (17324) NHS-ST-55,6-6,0-PA-AL (19419) NHS-ST-96,2-3,0-PA-M5 (25146) NHS-ST-60,0-4,0-KU-AL-ESD (23190)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Push rods (NHS)
Series : NHS-ST
Type : Starr
Version : ESD (< 10^5)
Accessory type : Customising accessory
Scope of delivery : Must be installed upon delivery, M4x20 T20 included
Outer dimensions (TxL) : 6.0 x 60 mm
Colour : Untreated
Mechanical data
Total length : 60 mm
Technical data
Tip diameter : 2.5 mm
Pushrod shaft diameter : 6 mm
Tip material : KU
Shaft material : AL
True running : 2768-mK
Installation : Screwed in
Thread : M4x10 mm
Tip length : 20 mm
Compatible with
Exchangeable kits version : Standard, ESD, RF
Manual test fixtures (MA) : MA 20xx
MA exchangeable kits (ATS MA) : ATS MAxx, ATS MA2xx, ATS MA3xx
Manual test fixture MA 2013/D/H/VPC-G12 Item 57325
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/HG Item 101930
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2014/D/H Item 100690
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/HG Item 100720
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/VPC-G12x-18 Item 53390
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2009/D/H Item 105127
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/PYLON-12 Item 51865
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/HF Item 54818
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2012/D/H
Manual test fixture MA 2012/D/H Item 48530
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/GR2270/71 Item 53350
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2011/D/H
Manual test fixture MA 2011/D/H Item 48590
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2013/D/H
Manual test fixture MA 2013/D/H Item 48620
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/PYLON-12 Item 53230
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/VPC-G12 Item 59830
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
S-Line assembly kit, bottom SBU-440-300-ATSMA13 Item 113322
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
Exchangeable kit ATS MA350/ESD Item 46490-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard and ESD versions, without internal interface
  • Signal transmission using VG multipoint connectors for individual configurations
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09/ESD Item 46245-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Rigid pin cover SNH-086-204-ATSMA11 Item 109248-KIT
  • Expansion kit for rigid pin units
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on pressure frame plate
  • Free overall height above the printed circuit board of 58 mm
Exchangeable kit ATS MA13/ESD Item 46254-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA360/ESD Item 46200-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard and ESD versions, without internal interface
  • Signal transmission using VG multipoint connectors for individual configurations
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/S-5/HF/AL/ESD Item 154111
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA12/S-7/CRS Item 108812
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2112, MA 3212
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
INGUN SELECTION ATS MA12/S-7/ESD
Exchangeable kit ATS MA12/S-7/ESD Item 46236-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/ESD Item 46248-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
S-Line assembly kit, bottom SBU-145-230-WL-ATSMA11 Item 113313
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
INGUN SELECTION ATS MA11/S-5/ESD
Exchangeable kit ATS MA11/S-5/ESD Item 46026-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA12/S-7
Exchangeable kit ATS MA12/S-7 Item 45903-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/HF/AL/ESD Item 154113
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA12/S-7/HF/AL/ESD Item 154112
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
INGUN SELECTION ATS MA360
Exchangeable kit ATS MA360 Item 45669-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard and ESD versions, without internal interface
  • Signal transmission using VG multipoint connectors for individual configurations
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA11
Exchangeable kit ATS MA11 Item 45900-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Rigid pin unit SNK-226-204-ATSMA12 Item 108791-KIT
  • Rigid pin units for reliable contacting in small grids, compatible with INGUN exchangeable kits for modular expansion
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on moving plate
  • Free overall height above the printed circuit board of 8 mm
  • FR4 precision plates ground to a smooth finish
Exchangeable kit ATS MA14/S-10/CRS Item 108814
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2114, MA 3214
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
S-Line assembly kit, bottom SBU-145-230-ATSMA11 Item 113312
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
Rigid pin cover SNH-226-204-ATSMA12 Item 108795-KIT
  • Expansion kit for rigid pin units
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on pressure frame plate
  • Free overall height above the printed circuit board of 58 mm
Rigid pin cover SNH-086-134-ATSMA09 Item 109244-KIT
  • Expansion kit for rigid pin units
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on pressure frame plate
  • Free overall height above the printed circuit board of 58 mm
Rigid pin cover SNH-481-274-ATSMA14 Item 109256-KIT
  • Expansion kit for rigid pin units
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on pressure frame plate
  • Free overall height above the printed circuit board of 58 mm
Exchangeable kit ATS MA14/ESD Item 46257-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Rigid pin unit SNK-086-134-ATSMA09 Item 109207-KIT
  • Rigid pin units for reliable contacting in small grids, compatible with INGUN exchangeable kits for modular expansion
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on moving plate
  • Free overall height above the printed circuit board of 8 mm
  • FR4 precision plates ground to a smooth finish
S-Line assembly kit, bottom SBU-285-230-WL-ATSMA12 Item 113151
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
INGUN SELECTION ATS MA13
Exchangeable kit ATS MA13 Item 45980-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/KONRAD Item 59640
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Rigid pin unit SNK-086-204-ATSMA11 Item 109217-KIT
  • Rigid pin units for reliable contacting in small grids, compatible with INGUN exchangeable kits for modular expansion
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on moving plate
  • Free overall height above the printed circuit board of 8 mm
  • FR4 precision plates ground to a smooth finish
Exchangeable kit ATS MA14/S-10/ESD Item 46242-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09/S-5 Item 45990-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
S-Line assembly kit, bottom SBU-145-160-WL-ATSMA09 Item 113306
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
Exchangeable kit ATS MA14/HF/AL/ESD Item 154014
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
INGUN SELECTION ATS MA350
Exchangeable kit ATS MA350 Item 46480-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard and ESD versions, without internal interface
  • Signal transmission using VG multipoint connectors for individual configurations
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA12/HF/AL/ESD Item 154012
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
INGUN SELECTION ATS MA11/S-5
Exchangeable kit ATS MA11/S-5 Item 45898-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
S-Line assembly kit, bottom SBU-440-300-WL-ATSMA13 Item 113323
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
Exchangeable kit ATS MA260/ESD Item 41225-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard and ESD versions, without internal interface
  • Signal transmission using VG multipoint connectors for individual configurations
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/S-10/HF/AL/ESD Item 154114
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
S-Line assembly kit, bottom SBU-540-300-ATSMA14 Item 113329
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
Exchangeable kit ATS MA11/HF/AL/ESD Item 154011
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
S-Line assembly kit, bottom SBU-145-160-ATSMA09 Item 113305
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
INGUN SELECTION ATS MA12
Exchangeable kit ATS MA12 Item 45904-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09 Item 45994-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09/S-5/ESD Item 46233-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Rigid pin unit SNK-382-274-ATSMA13 Item 109226-KIT
  • Rigid pin units for reliable contacting in small grids, compatible with INGUN exchangeable kits for modular expansion
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on moving plate
  • Free overall height above the printed circuit board of 8 mm
  • FR4 precision plates ground to a smooth finish
INGUN SELECTION ATS MA13/S-10/ESD
Exchangeable kit ATS MA13/S-10/ESD Item 46239-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
S-Line assembly kit, bottom SBU-285-230-ATSMA12 Item 113150
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4
INGUN SELECTION ATS MA13/S-10
Exchangeable kit ATS MA13/S-10 Item 45908-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Rigid pin unit SNK-482-274-ATSMA14 Item 109235-KIT
  • Rigid pin units for reliable contacting in small grids, compatible with INGUN exchangeable kits for modular expansion
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on moving plate
  • Free overall height above the printed circuit board of 8 mm
  • FR4 precision plates ground to a smooth finish
Exchangeable kit ATS MA13/HF/AL/ESD Item 154013
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Rigid pin cover SNH-381-274-ATSMA13 Item 109252-KIT
  • Expansion kit for rigid pin units
  • Available for all standard exchangeable kits ATS MAxx
  • Quick, easy mounting on pressure frame plate
  • Free overall height above the printed circuit board of 58 mm
Exchangeable kit ATS MA12/ESD Item 46250-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14 Item 45985-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/CRS Item 108813
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2113, MA 3213
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
Exchangeable kit ATS MA14/S-10 Item 45983-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA260
Exchangeable kit ATS MA260 Item 41220-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard and ESD versions, without internal interface
  • Signal transmission using VG multipoint connectors for individual configurations
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
S-Line assembly kit, bottom SBU-540-300-WL-ATSMA14 Item 113330
  • Precise, reliable contacting in small grids
  • Quick, easy installation
  • Extensive, detailed customisation guidelines
  • Plate material is deflection-resistant FR4