S-Line assembly kit, bottom SBU-440-300-ATSMA13 Item 113322

Downloads
Conformation of RoHS compliance (EN|PDF)
CAD file (INGUN_113322.STEP)
Document (INFO_4586.PDF)
Product datasheet (EN|pdf)
Document (113322__Kundenzeichnung.PDF)
Choose version
SBU-440-300-ATSMA13 (113322)
SBU-440-300-WL-ATSMA13 (113323) SBU-145-160-ATSMA09 (113305) SBU-145-160-WL-ATSMA09 (113306) SBU-285-230-ATSMA12 (113150) SBU-145-230-WL-ATSMA11 (113313) SBU-285-230-WL-ATSMA12 (113151) SBU-305-380-WL-VA2070S/i3070-5 (113339) SBU-540-300-ATSMA14 (113329) SBU-145-230-ATSMA11 (113312) SBU-305-380-VA2070S/i3070-5 (113338) SBU-440-300-ATSMA13 (113322) SBU-540-300-WL-ATSMA14 (113330)
Here you can optionally configure a new variant:
Technical data
General data
Product group : ATS MA upgrade kits
Subseries : ATS MAxx
Series : SBU
Version : S-Line standard
Scope of delivery : Unassembled
Dual-stage contacting : Yes
Weight : 6.83 kg
Min. temperature : + 10 °C
Max. temperature : + 60 °C
RoHS-compliant : RoHS-3;6c
Technical data
Useable area (WxD) : 440 x 300 mm
Outer dimensionS (WxDxH) : 454 x 300 x 26 mm
Compatible with
Exchangeable kit(s) (ATS) : ATS MA13
Manual test fixtures (MA) : MA 2013
Push rod NHS-ST-60,0-6,0-KU-AL-ESD Item 43611
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
INGUN SELECTION NHS-ST-60,0-2,5-KU-AL-ESD
Push rod NHS-ST-60,0-2,5-KU-AL-ESD Item 43612
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
INGUN SELECTION NHS-ST-60,0-2,5-POM-AL
Push rod NHS-ST-60,0-2,5-POM-AL Item 21615
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
INGUN SELECTION NHS-ST-60,0-6,0-PA-AL
Push rod NHS-ST-60,0-6,0-PA-AL Item 18870
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
Push rod NHS-ST-60,0-4,0-KU-AL-ESD Item 23190
  • Trusted push rods for reliable, rigid fixing of the PCB in the probe field against the force of the test probes
  • Robust, pressure-resistant design
  • Quick, easy installation
Manual test fixture MA 2013/D/H/HG Item 100720
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/VPC-G12 Item 57325
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2013/D/H
Manual test fixture MA 2013/D/H Item 48620
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/VPC-G12x-18 Item 53390
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/PYLON-12 Item 53230
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Exchangeable kit ATS MA13/ESD Item 46254-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA13/S-10/ESD
Exchangeable kit ATS MA13/S-10/ESD Item 46239-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/CRS Item 108813
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2113, MA 3213
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
Exchangeable kit ATS MA13/S-10/HF/AL/ESD Item 154113
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
INGUN SELECTION ATS MA13
Exchangeable kit ATS MA13 Item 45980-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/KONRAD Item 59640
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/HF/AL/ESD Item 154013
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
INGUN SELECTION ATS MA13/S-10
Exchangeable kit ATS MA13/S-10 Item 45908-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)