Interface block SB-P-PN-008-PK3-A Item 37821

Downloads
Conformation of RoHS compliance (EN|PDF)
Product datasheet (EN|pdf)
Document (37821__Kundenzeichnung.PDF)
CAD file (INGUN_37821.STEP)
Choose version
SB-P-PN-008-PK3-A (37821) INGUN SELECTION
SB-T-PN-008-PK3-A (37820) INGUN SELECTION SB-P-PN-008-PK3 (27622) INGUN SELECTION SB-T-PN-008-PK3 (27630) SB-P-PN-008-PK3-A (37821) INGUN SELECTION
Here you can optionally configure a new variant:
Technical data
General data
Product group : Interface blocks (SB)
Series : SB-PN
Type : Pneumatic block
Version : Device under test (DUT) side
Accessory type : Customising accessory
Component assembly : PKT-M-PK3-A
Weight : 0.021 kg
Min. temperature : - 30 °C
Max. temperature : + 120 °C
RoHS-compliant : RoHS-3
Technical data
Working distance : 15.1 +/- 0.5 mm
Centring pin : - mm
Connection : PDS-4-075-PUN
Number of poles : 8 (fixe Pos.)
Compressed air connection : PK-3
Typical compressed air : 6 bar
Compressed air lock : Yes
Compressed air quality : ISO 8573-1:2010
Compatible with
Compatible mating part 1 : SB-T-PN-008-PK3-A
MA exchangeable kits (ATS MA) : ATS MAxx
VA exchangeable kits (ATS VA) : ATS VIN2040, ATS VIN2040-2
PA exchangeable kits (ATS PA) : ATS PAZ100
Manual test fixture MA 2113/D/H/S-10/PYLON-12 Item 33688
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/PYLON-12 Item 33679
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2114/D/H/S-10/PYLON-12 Item 48980
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/PYLON-12 Item 51865
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113T/D/H/2xS-5/PYLON-12 Item 33680
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/HG/PYLON-12 Item 33678
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/PYLON-12 Item 33681
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/PYLON-12 Item 53230
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION SB-T-PN-008-PK3-A
Interface block SB-T-PN-008-PK3-A Item 37820
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of compressed air
Exchangeable kit ATS MA14/S-10/CRS Item 108814
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2114, MA 3214
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
Exchangeable kit ATS MA12/S-7/HF/AL/ESD Item 154112
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA09/S-5/ESD Item 46233-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA13/S-10/ESD
Exchangeable kit ATS MA13/S-10/ESD Item 46239-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/S-5/HF/AL/ESD Item 154111
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA14/S-10/ESD Item 46242-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/KONRAD Item 59640
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA11/S-5
Exchangeable kit ATS MA11/S-5 Item 45898-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA12/S-7/ESD
Exchangeable kit ATS MA12/S-7/ESD Item 46236-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA12/S-7
Exchangeable kit ATS MA12/S-7 Item 45903-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/CRS Item 108813
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2113, MA 3213
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
INGUN SELECTION ATS MA11/S-5/ESD
Exchangeable kit ATS MA11/S-5/ESD Item 46026-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09/S-5 Item 45990-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA12/S-7/CRS Item 108812
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2112, MA 3212
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
INGUN SELECTION ATS MA13/S-10
Exchangeable kit ATS MA13/S-10 Item 45908-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/HF/AL/ESD Item 154113
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA14/S-10/HF/AL/ESD Item 154114
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA14/S-10 Item 45983-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)