Manual test fixture MA 2113/D/H/S-10/HG/PYLON-12 Item 33679

Downloads
Conformation of RoHS compliance (EN|PDF)
Document (33679__Kundenzeichnung.PDF)
CAD file (INGUN_33679.STEP)
Product datasheet (EN|pdf)
CAD file (INGUN_33679_open.STEP)
Choose version
MA 2113/D/H/S-10/HG/PYLON-12 (33679)
MA 2113/D/H/S-10 (32500) INGUN SELECTION MA 2113/D/H/S-10/GR2270/71 (32920) MA 2113/D/H/S-10/HG/VPC-G12 (46040) MA 2113/D/H/S-10/KMFT (38871) MA 2113/D/H/S-10/VPC-G12 (35904) MA 2113/D/H/HG/S-10/MCP-Sco/OS (47540) MA 2113/D/H/S-10/HG (32700) INGUN SELECTION MA 2113/D/H/S-10/HG/GR2270/71 (33448) MA 2113/D/H/S-10/HG/VPC-G20x (49480) MA 2113/D/H/S-10/KS-i1000 (42600) MA 2113/D/H/S-10/MTS300 (33443) MA 2113/D/H/S-10/PYLON-12 (33688) MA 2113/D/H/S-10/SEICA-CD (108699) MA 2113/D/H/S-10/VPC-G12x (37799) MA 2113/SPEA 3030 (32701) MA 2113/D/H/S-10/HG/PYLON-12 (33679)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Manual test fixtures (MA)
Main series : MA xxxx
Subseries : MA 21xx
Series : MA 2113
Size : xx13
Test fixture type : Exchangeable test fixture
Contact stroke generation : Manual
Housing type : High desk housing
Max. interface signals : 1700
Interface blocks required : Test system side
Max. internal interface blocks : 10
Contacting direction : Single-sided (bottom)
Max. contact force : 2000 N
Approx. parallel contact stroke : 15 mm
Test system interface : Rohde & schwarz pylon
Weight : 17.5 kg
Min. temperature : + 10 °C
Max. temperature : + 60 °C
Low voltage : Yes, with suitable additional option
ESD-compliant : Yes, with suitable exchangeable kit
RoHS-compliant : RoHS-3;6c
Technical data
Test probe installation height, top : 16 mm
Test probe installation height, bottom : 10.5 mm
Test probe installation height, dual-stage, bottom : 16 mm
Free space above PCB : 58 mm
Force of gas pressure springs : 400 N (L: 200 N / R: 200 N)
Pressure frame closing force : 120 N
Pressure frame opening angle : 75 °
Standard version : Yes, with suitable exchangeable kit
Useable area, standard (WxD) : 440 x 310 mm
ESD version : Yes, with suitable exchangeable kit
Useable area, ESD (WxD) : 440 x 310 mm
Radio frequency version : Yes, with suitable exchangeable kit
Useable area, radio frequency (WxD) : 375 x 240 mm
Rigid pin version : No
Dual-stage version : Yes, with suitable additional option
Useable area, dual-stage (WxD) : 440 x 310 mm
Additional contacting unit (ZSK), top : Yes, with suitable additional option
Outer dimensions, open (WxDxH) : 654 x 564 x 749 mm
Outer dimensions, closed (WxDxH) : 654 x 618 x 362 mm
Interface block SB-HSD
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of high-speed digital (HSD) signals
Interface block SB-MB
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of several signal combinations
Interface block SB-BLP
  • Can be used in all test fixtures with internal or external pylon interface
  • To cover unused spaces for interface blocks
Interface block SB-SO
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable signal transmission
Interface block SB-SI
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-PN
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of compressed air
Interface block SB-HF
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of radio-frequency signals
  • Primarily equipped with INGUN test probes
Interface block SB-LL
  • Can be used in all test fixtures with internal or external pylon interface
  • Reliable transmission of light signals
  • High contact reliability and transmission quality
  • Consistently low contact loss
Interface block SB-HS
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-VA
  • Compatible with Pylon interface or Pylon receiver
  • To connect vacuum tube PG16
Fixture interface AS
  • Trusted fixture interfaces with precise guidance for the highest precision
  • Fully loaded or loaded versions for individual configurations
  • Available as component for popular test systems
Functional unit FB-MAxxxx
  • Upgrade kits to make operation easier, increase the testing reliability, and to reduce handling times
  • Available for manual test fixtures and exchangeable kits
  • Wide range of varying functions
Exchangeable kit ATS MA13
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Spare part kit ETK-MAxxxx
  • Available for each component as kit or individual part including assembly drawing for easy replacement and safe installation
  • Quick, easy maintenance
  • Easy replacement by operators on site