Interface block SB-P-LL-045-DM2,3 Item 29448

Downloads
Conformation of RoHS compliance (EN|PDF)
Product datasheet (EN|pdf)
CAD file (INGUN_29448.STEP)
Document (29448__Kundenzeichnung.PDF)
Choose version
SB-P-LL-045-DM2,3 (29448)
SB-T-LL-045-DM1,0-K (41017) SB-P-LL-045-DM1,0 (41020) SB-P-LL-045-DM2,3 (29448) SB-T-LL-020-OH3-K (38696) SB-T-LL-024-DK1,5-Z (30210) SB-T-LL-045-DM2,3-K (27618) SB-P-LL-024-DK1,5-Z (30211)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Interface blocks (SB)
Series : SB-LL
Type : Fibre optic block
Version : Device under test (DUT) side
Accessory type : Customising accessory
Component assembly : 45, fully loaded
Weight : 0.031 kg
Min. temperature : - 30 °C
Max. temperature : + 80 °C
RoHS-compliant : RoHS-3
Technical data
Working distance : 15.1 +/- 0.5 mm
Centring pin : - mm
Connection : Receptacle
Number of poles : 45
Fibre optic cladding diameter : 2,3
Fibre optic core diameter : 1.5 mm
Compatible with
Compatible mating part 1 : SB-T-LL-020-OH3-K
Compatible mating part 2 : SB-T-LL-045-DM2,3-K
MA exchangeable kits (ATS MA) : ATS MAxx
VA exchangeable kits (ATS VA) : ATS VIN2040, ATS VIN2040-2
PA exchangeable kits (ATS PA) : ATS PAZ100
Fibre optic cable LL-2,3-1,5 Item 39910
  • Robust polymer fibre optic cable for quick, simple plug fitting
  • Available with outer diameter 2.3 mm or 1.0 mm
  • Numerous mounting receptacles available from the ks range
INGUN SELECTION ATS MA11/S-5/ESD
Exchangeable kit ATS MA11/S-5/ESD Item 46026-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA13/S-10
Exchangeable kit ATS MA13/S-10 Item 45908-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/S-10/CRS Item 108814
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2114, MA 3214
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
Exchangeable kit ATS MA14/S-10/ESD Item 46242-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/CRS Item 108813
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2113, MA 3213
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
INGUN SELECTION ATS MA11/S-5
Exchangeable kit ATS MA11/S-5 Item 45898-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/S-10/HF/AL/ESD Item 154114
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA09/S-5 Item 45990-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA13/S-10/ESD
Exchangeable kit ATS MA13/S-10/ESD Item 46239-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA12/S-7/HF/AL/ESD Item 154112
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
INGUN SELECTION ATS MA12/S-7/ESD
Exchangeable kit ATS MA12/S-7/ESD Item 46236-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/S-10 Item 45983-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA09/S-5/ESD Item 46233-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA13/S-10/KONRAD Item 59640
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
INGUN SELECTION ATS MA12/S-7
Exchangeable kit ATS MA12/S-7 Item 45903-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA11/S-5/HF/AL/ESD Item 154111
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA13/S-10/HF/AL/ESD Item 154113
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA12/S-7/CRS Item 108812
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2112, MA 3212
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
Interface block SB-T-LL-045-DM2,3-K Item 27618
  • Can be used in all test fixtures with internal or external pylon interface
  • Reliable transmission of light signals
  • High contact reliability and transmission quality
  • Consistently low contact loss
Interface block SB-T-LL-020-OH3-K Item 38696
  • Can be used in all test fixtures with internal or external pylon interface
  • Reliable transmission of light signals
  • High contact reliability and transmission quality
  • Consistently low contact loss
Manual test fixture MA 2012/D/H/PYLON-12 Item 51865
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113T/D/H/2xS-5/PYLON-12 Item 33680
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/PYLON-12 Item 33681
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/HG/PYLON-12 Item 33679
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/PYLON-12 Item 53230
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2112/D/H/S-7/HG/PYLON-12 Item 33678
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2114/D/H/S-10/PYLON-12 Item 48980
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2113/D/H/S-10/PYLON-12 Item 33688
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Interchangeable test fixtures with and without pre-configured test system interface
  • Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
  • Modularly configurable signal transmission using interface blocks, which can be quickly detached
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring