Coaxial cable, pre-wired SE-EF316D-50MCXMG080SMAMG Item SE-EF316D-0016

Downloads
Conformation of RoHS compliance (EN|PDF)
Product datasheet (EN|pdf)
CAD file (INGUN_SE-EF316D-50MCXMG080SMAMG.STEP)
Choose version
SE-EF316D-50MCXMG080SMAMG (SE-EF316D-0016) INGUN SELECTION
SE-EF316D-50MCXMG080SMAMG (SE-EF316D-0016) INGUN SELECTION SE-EF316D-50MCXMW080 (SE-EF316D-0017) SE-EF316D-50MCXMW080SMAMG (SE-EF316D-0018) INGUN SELECTION SE-EF316D-50MCXMG080 (SE-EF316D-0015) INGUN SELECTION SE-EF316D-50SMAMG080SMAMG (SE-EF316D-0005)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Assemblies
Series : SE-EF316D
Sub-series : SE-EF316D plug
Min. temperature : - 40 °C
Max. temperature : + 105 °C
RoHS-compliant : RoHS-3
Cable data
Cable length : 80 cm
Cable type : ENVIROFLEX_316_D
Kink protection cable : Shrink-on sleeve, black, 20 mm
Attenuation Fmax : 2.21 dB
Connector data
Interface 1 : MCX
Interface gender 1 : M signal conductor male / plug
Version 1 : Straight
Interface 2 : SMA
Interface gender 2 : M signal conductor male / plug
Version 2 : Straight
Moment interface 2 : 45 cNm
Electrical data
Maximum frequency : 6 GHz
Impedance : 50 Ohm
Cable shielding : Double
Maximum performance : 45 W
Performance coefficient : 110 EF316D
Dielectric strength : 0.75 kV
Attenuation coefficient a : 0,71820 EF316D
Attenuation coefficient b : 0,16820 EF316D