General data
Product group : Board marker probes (ME)
Series : ME-E
Version : Electrical
Accessory type : Customising accessory
Outer dimensions (TxL) : 12 x 60 mm
Outer thread : M12 x 1
Lock nut width across flats : 14 mm
Marking type : Circle
Approx. marking Ø : 2 mm
Surface material : Hard / soft
Weight : 0.04 kg
Min. temperature : - 20 °C
Max. temperature : + 65 °C
RoHS-compliant : RoHS-3;6c
Technical data
Recommended working stroke : 1.5 mm
Recommended marking impulse : 1.0 s
Maximum stroke (ME) : 2.5 mm
Approx. compression at working stroke : 3.1 N
Marking tip : Scratching engraver
Engraver material : Solid carbide
Approx. engraver hardness : 1600 HV
Drive : Electric gear motor
Motor connection via : Cable
Rated voltage : 12 V DC
Rated output : 0.75 W
No-load current : 3.68 mA
Starting current : 106 mA
Connecting resistance : 114 Ohm
Max. load current : 81 mA
Max. torque : 54 mNm
Approx. idle speed : 180 U/min
Noise emission : Not relevant
Compatible with
Manual test fixtures (MA) : MA 20xx
Pneumatic test fixtures (PA) : PA xxxx
Vacuum test fixtures (VA) : VA xxxx
MA exchangeable kits (ATS MA) : ATS MAxx/xxx
VA exchangeable kits (ATS VA) : ATS VINxxx
PA exchangeable kits (ATS PA) : ATS PAZxxx, ATS PAxxxx
INGUN SELECTION VA 2070S/i3070-5
Vacuum test fixture VA 2070S/i3070-5 Item 4844-KIT
  • Vacuum test fixture with parallel closing vacuum cassette for testing large PCB quantities
  • Robust, maintenance-friendly design with outstanding service life
  • Available for Keysight i3070 test system
  • Increased ease of use without significant closing forces
  • Single-stage and dual-stage versions
  • Single-stage and dual-stage versions
  • Detailed accompanying documents (e.g., customising guidelines)
Vacuum test fixture VA 2073L/i3070-5 Item 8326
  • Vacuum test fixture with parallel closing vacuum cassette for testing large PCB quantities
  • Robust, maintenance-friendly design with outstanding service life
  • Stand-alone test fixtures with pre-configured test system interface
  • Available for Keysight i3070 test system
  • Increased ease of use without significant closing forces
  • Single-stage and dual-stage versions
  • Detailed accompanying documents (e.g., customising guidelines)
Manual test fixture MA 2012/D/H/PYLON-12 Item 51865
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2011/D/H
Manual test fixture MA 2011/D/H Item 48590
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/HG Item 100720
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/HG Item 101930
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/HF Item 54818
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/PYLON-12 Item 53230
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/VPC-G12x-18 Item 53390
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/GR2270/71 Item 53350
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2014/D/H Item 100690
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2012/D/H/VPC-G12 Item 59830
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2012/D/H
Manual test fixture MA 2012/D/H Item 48530
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2013/D/H/VPC-G12 Item 57325
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
INGUN SELECTION MA 2013/D/H
Manual test fixture MA 2013/D/H Item 48620
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Manual test fixture MA 2009/D/H Item 105127
  • Manual test fixtures with parallel closing drive mechanism for testing medium PCB quantities with the highest quality and precision
  • Stand-alone test fixtures with and without pre-configured test system interface
  • Permanently mounted, non-exchangeable kits in standard, ESD and RF versions that can be used without readjustment
  • Direct, hard-wired signal transmission
  • Detailed accompanying documents (e.g., customising guidelines)
  • Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Pneumatic test fixture PA 2130/D/H Item 20598
  • Pneumatic test fixture with parallel closing drive for testing medium PCB quantities
  • Robust, durable test fixture with cam disc
  • Standard and ESD exchangeable kits that can be exchanged quickly and without tools
  • Increased ease of use without significant closing forces
  • Rapid contacting movement
Exchangeable kit ATS PAZ400 Item 28491
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard and ESD versions, with or without internal interface
  • Signal transmission using VG multipoint connectors or contact terminals for individual configurations
Exchangeable kit ATS PAZ215 Item 18958
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard and ESD versions, with or without internal interface
  • Signal transmission using VG multipoint connectors or contact terminals for individual configurations