Manual test fixture MA 2114/D/H/S-10/HG Item 42290

Downloads
Conformation of RoHS compliance (EN|PDF)
CAD file (INGUN_42290.STEP)
Document (42290__Kundenzeichnung.PDF)
CAD file (INGUN_42290_open.STEP)
Product datasheet (EN|pdf)
Choose version
MA 2114/D/H/S-10/HG (42290)
MA 2114/D/H/S-10 (34350) MA 2114/D/H/S-10/HG (42290) MA 2114/D/H/S-10/PYLON-12 (48980)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Manual test fixtures (MA)
Main series : MA xxxx
Subseries : MA 21xx
Series : MA 2114
Size : xx14
Test fixture type : Exchangeable test fixture
Contact stroke generation : Manual
Housing type : High desk housing
Max. interface signals : 1700
Interface blocks required : Test system side
Max. internal interface blocks : 10
Contacting direction : Single-sided (bottom)
Max. contact force : 2000 N
Approx. parallel contact stroke : 15 mm
Test system interface : Not pre-wired
Min. temperature : + 10 °C
Max. temperature : + 60 °C
Low voltage : Yes
ESD-compliant : Yes, with suitable exchangeable kit
RoHS-compliant : RoHS-3;6c
Technical data
Test probe installation height, top : 16 mm
Test probe installation height, bottom : 10.5 mm
Test probe installation height, dual-stage, bottom : 16 mm
Free space above PCB : 58 mm
Pressure frame closing force : 120 N
Force of gas pressure springs : 500 N (L: 200 N / R: 300 N)
Pressure frame opening angle : 69 °
Standard version : Yes, with suitable exchangeable kit
Useable area, standard (WxD) : 540 x 310 mm
ESD version : Yes, with suitable exchangeable kit
Useable area, ESD (WxD) : 540 x 310 mm
Radio frequency version : No
Rigid pin version : No
Dual-stage version : Yes, with suitable additional option
Useable area, dual-stage (WxD) : 540 x 310 mm
Additional contacting unit (ZSK), top : Yes, with suitable additional option
Outer dimensions, open (WxDxH) : 748 x 533 x 753 mm
Outer dimensions, closed (WxDxH) : 748 x 584 x 370 mm
Exchangeable kit ATS MA14/HF/AL/ESD Item 154014
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA14/S-10 Item 45983-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14 Item 45985-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/S-10/ESD Item 46242-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/ESD Item 46257-KIT
  • Quick, tool-free set-up, can be used without readjustment
  • Available in standard, ESD, and RF versions, with or without internal interface
  • Modularly configurable signal transmission with internal interfaces
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Robust, durable design
  • Can be customised using functional units for individual configurations
  • Detailed accompanying documents (e.g., customising guidelines)
Exchangeable kit ATS MA14/S-10/HF/AL/ESD Item 154114
  • Reliable, interference-free radio frequency contacting and measurement of radio frequency signals
  • Outstanding shielding attenuation > 60 dB in the frequency range up to 6 GHz
  • Radio-frequency and RF-compatible shielding from external and internal interference signals
  • Safe to use in MA xxxx basic units
  • Quick, tool-free set-up - ready for use without readjustment
Exchangeable kit ATS MA14/S-10/CRS Item 108814
  • Reliable ICT/FCT tests in the fully automated inline test system and in the manual test fixture
  • Replacement kit for CRS test system SMART-Inline, IPS 19-2 and manual test fixture MA 2114, MA 3214
  • Modularly configurable signal transmission with internal interfaces
  • Quick, tool-free set-up, can be used without readjustment
  • Pressure plate unit and probe plate unit can be screwed together with stacking screws to form a unit with protected probe field
  • Designed for tooling pins with head length = 16 mm (FS-X,XX-RD-16-02)
Interface block SB-T-HF-016-0,7GHz-01 Item 38125
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-008-6GHz-02-Z Item 42217
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-SI-170-4A-Z Item 38690
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-016-2GHz-05-Z Item 38137
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-LL-045-DM2,3-K Item 27618
  • Can be used in all test fixtures with internal or external pylon interface
  • Reliable transmission of light signals
  • High contact reliability and transmission quality
  • Consistently low contact loss
INGUN SELECTION SB-T-PN-008-PK3-A
Interface block SB-T-PN-008-PK3-A Item 37820
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of compressed air
Interface block SB-T-MB-20/20-30A/DM2,3-K Item 45303
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of several signal combinations
Interface block dummy plate SB-B-BLP-ALU Item 2487
  • Can be used in all test fixtures with internal or external pylon interface
  • To cover unused spaces for interface blocks
Interface block SB-T-HF-004-18GHz Item 35534
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HS-002-50A Item 31549
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
INGUN SELECTION SB-T-HS-008-50A
Interface block SB-T-HS-008-50A Item 35549
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-T-HF-008-6GHz-03-Z Item 42216
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-01-Z Item 38155
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HS-034-20A Item 31011
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-T-HF-016-2GHz-02-Z Item 38140
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-10-Z Item 38132
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-LL-020-OH3-K Item 38696
  • Can be used in all test fixtures with internal or external pylon interface
  • Reliable transmission of light signals
  • High contact reliability and transmission quality
  • Consistently low contact loss
Interface block SB-T-HF-016-0,7GHz-12 Item 38114
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-004-18GHz-02 Item 55755
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-04-Z Item 38153
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-11-Z Item 38131
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-07-Z Item 38150
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-PN-008-PK3 Item 27630
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact loss
  • High contact reliability and transmission quality
  • Reliable transmission of compressed air
Interface block SB-T-HF-008-6GHz-05-Z Item 41825
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-02-Z Item 38154
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-008-6GHz-04-Z Item 42215
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-LL-024-DK1,5-Z Item 30210
  • Can be used in all test fixtures with internal or external pylon interface
  • Reliable transmission of light signals
  • High contact reliability and transmission quality
  • Consistently low contact loss
Interface block SB-T-HF-008-6GHz-07-Z Item 41823
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
INGUN SELECTION SB-T-HS-024-30A
Interface block SB-T-HS-024-30A Item 27628
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-T-HF-016-0,7GHz-02 Item 38124
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-14-Z Item 38143
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-SI-170-4A-N-Z Item 38694
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-016-0,7GHz-13 Item 38113
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-004-18GHz-03 Item 55756
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz Item 31004
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-MB-20/4-30A/PK3-A Item 50582
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of several signal combinations
Interface block SB-T-HS-004-50A Item 37699
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-T-SI-170-4A-N Item 31006
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-SI-040-4A-N-Z Item 44226
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-016-2GHz-01-Z Item 38141
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-06-Z Item 38136
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-SI-136-4A-Z Item 109465
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
INGUN SELECTION SB-T-HS-024-30A-Z
Interface block SB-T-HS-024-30A-Z Item 38699
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-T-HF-016-2GHz-15-Z Item 38127
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
INGUN SELECTION SB-T-SI-085-4A
Interface block SB-T-SI-085-4A Item 30181
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-008-6GHz-01-Z Item 42218
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-MB-20/4-30A/PK3 Item 32020
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances
  • High contact reliability and transmission quality
  • Reliable transmission of several signal combinations
Interface block SB-T-HF-016-0,7GHz-11 Item 38115
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz-09 Item 38117
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-SI-040-4A-N Item 44225
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-016-0,7GHz-08 Item 38118
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-SI-170-4A-RD Item 51690
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
INGUN SELECTION SB-T-SI-136-4A
Interface block SB-T-SI-136-4A Item 36800
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-016-4GHz-03-Z Item 39681
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-08-Z Item 38134
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-09-Z Item 38148
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-06-Z Item 38151
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
INGUN SELECTION SB-T-HS-045-30A
Interface block SB-T-HS-045-30A Item 30963
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-T-SI-040-4A-Z Item 42342
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-016-2GHz-13-Z Item 38129
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz-06 Item 38120
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz-14 Item 38112
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-08-Z Item 38149
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-11-Z Item 38146
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-15-Z Item 38142
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz-04 Item 38122
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HS-045-30A-Z Item 38697
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of high current signals
Interface block SB-T-HF-016-2GHz-14-Z Item 38128
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-008-6GHz-06-Z Item 41824
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-10-Z Item 38147
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz-03 Item 38123
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-12-Z Item 38130
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-LL-045-DM1,0-K Item 41017
  • Can be used in all test fixtures with internal or external pylon interface
  • Reliable transmission of light signals
  • High contact reliability and transmission quality
  • Consistently low contact loss
Interface block SB-T-HF-016-2GHz-Z Item 34581
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-05-Z Item 38152
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-07-Z Item 38135
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz-15 Item 38111
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz-05 Item 38121
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-04-Z Item 38138
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-0,7GHz-07 Item 38119
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-Z Item 34996
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-4GHz-13-Z Item 38144
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-SI-085-4A-Z Item 42346
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
INGUN SELECTION SB-T-SI-040-4A
Interface block SB-T-SI-040-4A Item 37075
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-016-4GHz-12-Z Item 38145
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-09-Z Item 38133
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-008-6GHz-Z Item 41165
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-016-2GHz-03-Z Item 38139
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
Interface block SB-T-HF-004-18GHz-01 Item 55754
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation
INGUN SELECTION SB-T-SI-170-4A
Interface block SB-T-SI-170-4A Item 27616
  • Equipped with INGUN test probes
  • Uniformly parallel wire-wrap posts
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Reliable transmission of low voltage signals
  • Pre-assembled plug connectors as connection accessories
Interface block SB-T-HF-016-0,7GHz-10 Item 38116
  • Equipped with INGUN test probes
  • Can be used in all test fixtures with internal or external pylon interface
  • Consistently low contact resistances and replicable measured values
  • High contact reliability and transmission quality
  • Prozesssichere Übertragung von Hochfrequenzsignalen im Rahmen der Spezifikation