Receptacle A KS-899 30 M-R-T Item KS-89930M-R-T

Downloads
Conformation of RoHS compliance (EN|PDF)
CAD file (INGUN_KS-899_30_M-R-T.STEP)
Product datasheet (EN|pdf)
Choose version
KS-899 30 M-R-T (KS-89930M-R-T) INGUN SELECTION
KS-899 30 M-R (KS-89930M-R) INGUN SELECTION KS-899 30 M-R-T (KS-89930M-R-T) INGUN SELECTION
Here you can optionally configure a new variant:
Technical data
General data
Product group : Receptacles (KS)
Series : KS-899
Sub-series : KS-899 M screw-in version
Type of receptacle connection : Solder
Press ring : No
Surface area : Gold
Collar diameter : 1.84 mm
Collar height : 3.4 mm
Knurl : Yes
Vacuum-tight : No
RoHS-compliant : RoHS-3;6c
Mounting hole
Mounting hole in CEM1 : 1.67 - 1.68 mm
Mounting hole in FR4 : 1.67 - 1.68 mm
Mechanical data
Total length : 24.5 mm
Outer diameter : 1.67 mm
Spring-loaded test probe GKS-899 306 180 A 0702 M Item GKS-899-0027
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 302 075 A 1502 M Item GKS-899-0022
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 306 100 A 1502 M Item GKS-899-0046
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 306 180 A 3002 M
Spring-loaded test probe GKS-899 306 180 A 3002 M Item GKS-899-0008
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 306 100 A 3002 M Item GKS-899-0047
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 313 061 A 3002 M Item GKS-899-0024
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 313 061 A 2502 M Item GKS-899-0094
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 305 075 A 1502 M
Spring-loaded test probe GKS-899 305 075 A 1502 M Item GKS-899-0010
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 306 130 A 2502 M Item GKS-899-0074
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 305 075 A 2502 M Item GKS-899-0080
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 305 075 A 3002 M
Spring-loaded test probe GKS-899 305 075 A 3002 M Item GKS-899-0005
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 302 150 A 1502 M
Spring-loaded test probe GKS-899 302 150 A 1502 M Item GKS-899-0023
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 302 150 A 0702 M Item GKS-899-0031
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 303 180 A 0702 M Item GKS-899-0042
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 306 130 A 1502 M
Spring-loaded test probe GKS-899 306 130 A 1502 M Item GKS-899-0001
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 302 065 A 3002 M Item GKS-899-0035
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 306 130 A 0702 M Item GKS-899-0019
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 313 061 A 1502 M Item GKS-899-0016
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 302 065 A 0702 M Item GKS-899-0060
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 313 061 A 0702 M Item GKS-899-0040
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 201 075 A 2502 M Item GKS-899-0057
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 305 065 A 3002 M
Spring-loaded test probe GKS-899 305 065 A 3002 M Item GKS-899-0013
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 303 180 A 1502 M
Spring-loaded test probe GKS-899 303 180 A 1502 M Item GKS-899-0009
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 201 075 A 1502 M Item GKS-899-0003
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 305 065 A 1502 M
Spring-loaded test probe GKS-899 305 065 A 1502 M Item GKS-899-0006
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 302 075 A 3002 M Item GKS-899-0036
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 303 180 A 3002 M Item GKS-899-0011
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 305 065 A 2502 M Item GKS-899-0039
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 302 065 A 1502 M Item GKS-899-0015
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 303 180 A 2502 M Item GKS-899-0050
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 302 075 A 0702 M Item GKS-899-0020
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 305 075 A 0702 M Item GKS-899-0028
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 201 075 A 3002 M Item GKS-899-0004
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 201 075 A 0702 M Item GKS-899-0030
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 306 100 A 2502 M Item GKS-899-0090
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 306 130 A 3002 M
Spring-loaded test probe GKS-899 306 130 A 3002 M Item GKS-899-0007
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 305 065 A 0702 M Item GKS-899-0012
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 306 100 A 0702 M Item GKS-899-0076
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 302 150 A 3002 M Item GKS-899-0034
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
Spring-loaded test probe GKS-899 306 180 A 2502 M Item GKS-899-0052
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION GKS-899 306 180 A 1502 M
Spring-loaded test probe GKS-899 306 180 A 1502 M Item GKS-899-0002
  • Screw-in test probes for applications with possible vibrations or unwanted side and axial forces (migration of the test probe out of the receptacle is reliably prevented)
  • The screw-in test probe is securely installed in the KS using a torque screwdriver and bit tool. The required screw-in torque is applied via a square post on the receptacle.
INGUN SELECTION T-899 305 070 400 150A1502M
Step probe T-899 305 070 400 150A1502M Item T-899-0004
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 070 400 150A3002M Item T-899-0006
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 400 150A3002M Item T-899-0014
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 400 150A0702M Item T-899-0008
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
INGUN SELECTION T-899 305 065 400 150A1502M
Step probe T-899 305 065 400 150A1502M Item T-899-0001
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 340 150A3002MG Item T-899-0016
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 340 150A1502MG Item T-899-0005
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 302 065 210 150A1502M Item T-899-0003
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 280 150A3002M Item T-899-0023
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 280 150A1502M Item T-899-0002
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 270 150A0702MG Item T-899-0015
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 270 150A1502MG Item T-899-0009
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths
Step probe T-899 305 065 270 150A3002MG Item T-899-0064
  • Step probes are used to test the correct position of the contact terminals (contact lamellae) in the plug housings. A connection test can be carried out at the same time. Contact will only occur when the tip of the step probe is correctly positioned
  • For optimum contacting, various tip styles are available in various tip ø, disc ø and pin lengths