Receptacle KS-112 30 E2 Item KS-11230E2

Downloads
Conformation of RoHS compliance (EN|PDF)
Product datasheet (EN|pdf)
CAD file (INGUN_KS-112_30_E2.STEP)
Choose version
KS-112 30 E2 (KS-11230E2) INGUN SELECTION
KS-112 30 G8 (KS-11230G8) INGUN SELECTION KS-112 47 E5 (KS-11247E5) KS-112 47-15 (KS-11247-15) KS-112 47 E2 (KS-11247E2) KS-112 30 E5 (KS-11230E5) INGUN SELECTION KS-112 47 (KS-11247) INGUN SELECTION KS-112 30 (KS-11230) INGUN SELECTION KS-112 35 (KS-11235) INGUN SELECTION KS-112 30 E2 (KS-11230E2) INGUN SELECTION KS-112 47 G8 (KS-11247G8) INGUN SELECTION KS-112 23 (KS-11223) INGUN SELECTION
Here you can optionally configure a new variant:
Technical data
General data
Product group : Receptacles (KS)
Series : KS-112
Sub-series : KS-112 press-in version
Type of receptacle connection : Solder
Press ring : No
Surface area : Gold
Collar diameter : 2.2 mm
Collar height : 2 mm
Knurl : No
Vacuum-tight : No
RoHS-compliant : RoHS-3;6c
Mounting hole
Mounting hole in CEM1 : 1.98 - 2.00 mm
Mounting hole in FR4 : 1.99 - 2.01 mm
Mechanical data
Total length : 30 mm
Outer diameter : 2 mm
Spring-loaded test probe GKS-912 214 180 A 3002 C Item GKS-912-2709
  • Robust test probes with distinctive collar (stop) on the barrel
  • Optimum adjustment of the stroke ratios in the test fixture: The collar is available in different heights, which, in combination with the receptacles, allows a range of installation heights
  • Version with central beading ensure low wobble for contacting small test points
  • Stainless steel versions for temperatures from -100 °C up to +200 °C available
Spring-loaded test probe GKS-112
  • Robust test probes with distinctive collar (stop) on the barrel
  • Optimum adjustment of the stroke ratios in the test fixture: The collar is available in different heights, which, in combination with the receptacles, allows a range of installation heights
  • Stainless steel versions for temperatures from -100 °C up to +200 °C available
Spring-loaded test probe GKS-422
  • Robust test probes with distinctive collar (stop) on the barrel
  • Optimum adjustment of the stroke ratios in the test fixture: The collar is available in different heights, which, in combination with the receptacles, allows a range of installation heights
  • Version with central beading ensure low wobble for contacting small test points
  • Stainless steel versions for temperatures from -100 °C up to +200 °C available
INGUN E-TYPE® E-422
  • Highest contact reliability under challenging test conditions without additional stress on the DUT: up to 25% larger contact surface between test probe and DUT
  • When hitting the test surface a spring force up to 100% higher than a standard GKS is available, but the same spring force as a standard GKS is achieved at the working stroke.
  • Dimensions equivalent to the standard GKS series
Spring-loaded test probe GKS-912
  • Robust test probes with distinctive collar (stop) on the barrel
  • Optimum adjustment of the stroke ratios in the test fixture: The collar is available in different heights, which, in combination with the receptacles, allows a range of installation heights
  • Version with central beading ensure low wobble for contacting small test points
  • Stainless steel versions for temperatures from -100 °C up to +200 °C available
High-current probe HSS-118
  • Trusted, robust high-current probes, optimally sized for current load capacity ratio
  • Low-Ohm probe with Ri typical: < 10 mOhm
  • For use in function and burn-in tests
  • Large selection of tip styles and spring forces for optimum contact with DUT
  • Optimum adjustment of the stroke ratios in the test fixture: The test probe collar is available in different heights, which, in combination with the receptacles, allows a range of installation heights
Spring-loaded test probe GKS-412
  • Robust test probes with distinctive collar (stop) on the barrel
  • Optimum adjustment of the stroke ratios in the test fixture: The collar is available in different heights, which, in combination with the receptacles, allows a range of installation heights