Spring-loaded test probe GKS-746 314 200 A 1502 M Item GKS-746-0005

Downloads
Conformation of RoHS compliance (EN|PDF)
CAD file (INGUN_GKS-746_314_200_A_xx02_M.STEP)
Product datasheet (EN|pdf)
Choose version
GKS-746 314 200 A 1502 M (GKS-746-0005)
GKS-746 320 110 045 A 3002 M (GKS-746-0012) GKS-746 320 150 100 A 3002 M (GKS-746-0015) GKS-746 314 200 A 3002 M (GKS-746-0014) GKS-746 320 150 050 A 1502 M (GKS-746-0001) INGUN SELECTION GKS-746 305 064 A 1502 M (GKS-746-0007) GKS-746 314 200 A 1502 M (GKS-746-0005) GKS-746 320 110 045 A 1502 M (GKS-746-0002) GKS-746 320 150 100 A 1502 M (GKS-746-0004) GKS-746 320 200 080 A 1502 M (GKS-746-0003) INGUN SELECTION GKS-746 305 064 A 0902 M (GKS-746-0016) GKS-746 305 064 A 3002 M (GKS-746-0013) GKS-746 320 150 050 A 3002 M (GKS-746-0006) GKS-746 320 200 080 A 3002 M (GKS-746-0011)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Screw-in test probe
Sub-product group : Non-rotating test probes
Series : GKS-746 M screw-in
Grid : 2.54 mm
Contacting from : Pad, pin, posts
Magnetic : Yes
Installation type : Screw-in
Quick-exchange system : Yes
Adjustable installation height : No
Non-rotating : Yes
Continuous plunger : ø0,8 x 0,46 x 4,4
Screw-in torque : 3 - 5 cNm
Compatible receptacle(s) : KS-746 M
Min. temperature : - 40 °C
Max. temperature : + 80 °C
RoHS-compliant : RoHS-3;6c
Electrical data
Current load capacity / rated current : 8 A
Typical resistance (Ri) : < 30 mOhm
Mechanical data
Total length : 40.2 mm
Barrel diameter : 1.65 mm
Maximum stroke : 4.4 mm
Spring pre-load : 0.5 N
Collar height : 02
Spring force at working stroke : 1.5 N
Working stroke : 4 mm
Tip style data
Tip style : 14 4-point crown, self-cleaning
Tip diameter : 2 mm
Tip style surface : A gold
Tip style material : 3 CuBe