Product information "MA 3211/D/H/S-5"
- Manual test fixtures with parallel closing drive mechanism for testing large PCB quantities with the highest quality and precision
- Ultra-robust long-life test fixture with increased parallel stroke of 21 mm
- Interchangeable set of test fixtures without preconfigured test system interface
- Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
- Modularly configurable signal transmission using interface blocks, which can be quickly detached
- Detailed accompanying documents (e.g., customising guidelines)
- Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
| Additional contacting unit (ZSK), top: | Yes, with suitable additional option |
|---|---|
| Approx. parallel contact stroke: | 22 mm [.866 in] |
| Contacting direction: | Double-sided (top/bottom) |
| Contact stroke generation: | Manual |
| Dual-stage version: | Yes, with compatible additional option |
| ESD-compliant: | Yes, with compatible exchangeable kit |
| ESD version: | Yes, with compatible exchangeable kit |
| Force of gas pressure springs: | 200 N (L: 100 N / R: 100 N) |
| Free space above PCB: | 58 mm [2.28 in] |
| Housing type: | Desk housing |
| Interface blocks required: | Test system side |
| Low voltage: | Yes, with suitable additional option |
| Main series: | MA xxxx |
| Max. contact force: | 2,000 N [7,193 ozf] |
| Max. interface signals: | 5, 850 |
| Max. internal interface blocks: | 5 |
| Max. temperature: | 60 °C [140 °F] |
| Min. temperature: | 10 °C [50 °F] |
| Outer dimensions, closed (WxDxH): | 320 x 533 x 270 mm [12.5 x 20.9 x 10.6 in] |
| Outer dimensions, open (WxDxH): | 320 x 464 x 637 mm [12.5 x 18.2 x 25 in] |
| Pressure frame closing force: | 70 N [251 ozf] |
| Pressure frame opening angle: | 69 ° |
| Product group: | Manual test fixtures (MA) |
| Radio frequency version: | Yes, with compatible exchangeable kit |
| Rigid pin version: | No |
| RoHS-compliant: | Yes |
| Series: | MA 3211 |
| Size: | xx11 |
| Standard version: | Yes, with compatible exchangeable kit |
| Subseries: | MA 32xx |
| Test fixture type: | Exchangeable test fixture |
| Test probe installation height, bottom: | 10.5 mm [.413 in] |
| Test probe installation height, dual-stage, bottom: | 16 mm [.629 in] |
| Test probe installation height, top: | 16 mm [.629 in] |
| Test system interface: | Not pre-wired |
| Useable area, ESD (WxD): | 150 x 240 mm [5.9 x 9.44 in] |
| Useable area, dual-stage (WxD): | 150 x 240 mm [5.9 x 9.44 in] |
| Useable area, radio frequency (WxD): | 100 x 160 mm [3.93 x 6.29 in] |
| Useable area, standard (WxD): | 150 x 240 mm [5.9 x 9.44 in] |
| Useable area: long edge: | 160 mm [6.29 in], 240 mm [9.44 in] |
| Useable area: short edge: | 100 mm [3.93 in], 150 mm [5.9 in] |
| Weight: | 11.7 kg [25.7 lbs] |
Login
- Manual test fixtures with parallel closing drive mechanism for testing large PCB quantities with the highest quality and precision
- Ultra-robust long-life test fixture with increased parallel stroke of 21 mm
- Interchangeable set of test fixtures without preconfigured test system interface
- Standard, ESD, and RF exchangeable kits that can be installed without tools and used without readjustment
- Modularly configurable signal transmission using interface blocks, which can be quickly detached
- Detailed accompanying documents (e.g., customising guidelines)
- Maximum opening angle may vary due to the length tolerance of +/- 2 mm of the gas spring
Other products in this series:
- Interface blocks required: Test system side
- Weight: 11.7 kg [25.7 lbs]
- Housing type: Desk housing
- Max. internal interface blocks: 5
- Product group: Manual test fixtures (MA)
- Contact stroke generation: Manual
- Max. contact force: 2,000 N [7,193 ozf]
- Max. temperature: 60 °C [140 °F]
- Test fixture type: Exchangeable test fixture
- Max. interface signals: 850
- Contacting direction: Double-sided (top/bottom)
- Size: xx11
- Min. temperature: 10 °C [50 °F]
- Max. interface signals: 5
- Test system interface: Not pre-wired
- Series: MA 3211
- Approx. parallel contact stroke: 22 mm [.866 in]
- RoHS-compliant: Yes
- Subseries: MA 32xx
- ESD-compliant: Yes, with compatible exchangeable kit
- Main series: MA xxxx
- Low voltage: Yes, with suitable additional option
- Radio frequency version: Yes, with compatible exchangeable kit
- Pressure frame opening angle: 69 °
- Dual-stage version: Yes, with compatible additional option
- Standard version: Yes, with compatible exchangeable kit
- Outer dimensions, closed (WxDxH): 320 x 533 x 270 mm [12.5 x 20.9 x 10.6 in]
- ESD version: Yes, with compatible exchangeable kit
- Test probe installation height, bottom: 10.5 mm [.413 in]
- Outer dimensions, open (WxDxH): 320 x 464 x 637 mm [12.5 x 18.2 x 25 in]
- Useable area, ESD (WxD): 150 x 240 mm [5.9 x 9.44 in]
- Free space above PCB: 58 mm [2.28 in]
- Rigid pin version: No
- Additional contacting unit (ZSK), top: Yes, with suitable additional option
- Test probe installation height, dual-stage, bottom: 16 mm [.629 in]
- Useable area, radio frequency (WxD): 100 x 160 mm [3.93 x 6.29 in]
- Useable area, dual-stage (WxD): 150 x 240 mm [5.9 x 9.44 in]
- Useable area, standard (WxD): 150 x 240 mm [5.9 x 9.44 in]
- Pressure frame closing force: 70 N [251 ozf]
- Force of gas pressure springs: 200 N (L: 100 N / R: 100 N)
- Test probe installation height, top: 16 mm [.629 in]