Vacuum test fixture VA 2601-2e/F/H/GR228x15/7 Item 27051

Downloads
Conformation of RoHS compliance (EN|PDF)
Product datasheet (EN|pdf)
Choose version
VA 2601-2e/F/H/GR228x15/7 (27051)
Here you can optionally configure a new variant:
Technical data
General data
Product group : Vacuum test fixture (VA)
Main series : VA xxxx
Series : VA 26xx
Series : VA 2601-2e
Size : x601-2e
Test system interface : Test station GR 228x 15/07
Test fixture type : Stand-alone test fixture
Contact stroke generation : Vacuum
Housing type : Flat housing
Max. interface signals : 560
Interface blocks required : No
Contacting direction : One-sided, dual-stage
Max. contact force : 14000 N
Approx. parallel contact stroke : 12 mm
Weight : 12.6 kg
Min. temperature : + 10 °C
Max. temperature : + 60 °C
RoHS-compliant : -
Technical data
Test probe installation height, bottom : 16 mm
Test probe installation height, dual-stage, bottom : 21.5 mm
Standard version : Yes
Useable area, standard (WxD) : 385 x 290 mm
ESD version : No
Radio frequency version : No
Rigid pin version : No
Dual-stage version : Yes
Additional contacting unit (ZSK), top : Yes, with suitable additional option
Outer dimensions, closed (WxDxH) : 554 x 487 x 140 mm